SPL-SSW-103 / 6–100 KG

IP68 stainless single point load cell.

One documented bench-cell design. Six rated capacities. A 500 × 400 mm reference platform for OEM weighing modules.

SPL-SSW-103 stainless single point cell with round sealed flexure window, two visible top mounting holes, two left-end holes and right cable
SPL-SSW-103 source-product reference, cleaned from its actual catalogue photograph; confirm the supplied configuration.

Fit the sensor to the whole loaded platform.

Use this reference to review wet-process bench scales, filling platforms and OEM weighing equipment. Start with the empty platen, fixtures and cable forces, then add the product and application load cases. The capacity selector below keeps each rated variant separate.

The stainless body has a nominal 150 × 25 × 40 mm envelope. The source outline shows 19 mm local hole spacing and a 100 mm span between the inner mounting positions. Use the numerical callouts and the supplied revision before making a fixture.

Allow space beyond the body for the cable-entry boss, shown as 14 mm diameter with 7.5 mm projection. Confirm the active mounting faces, bolt approach and cable termination on the supplied drawing; do not assume all depicted mounting faces are used together.

Screen gross load and the platform envelope
Rated capacity
6 / 10 / 20 / 30 / 50 / 100 kg
Reference platform
500 × 400 mm
Protection declaration
IP68 in the 2023 source catalogue
Mounting
M6; 12 mm depth callouts
Signal
2.0 ±10% mV/V; 6 conductors plus shield
Material
Stainless steel; exact alloy grade to confirm

CLEANING EXPOSURE / ORDER EVIDENCE

Specify the water exposure before the sample order.

The IP68 row identifies the source design. Request immersion depth, duration, cable-entry conditions and the actual supplied test record. For a hot pressure-jet process, specify temperature, pressure, distance, cleaning chemistry and cycle frequency.

Stainless grade, weld process and hygienic suitability remain order-specific review items. A photograph of a sealed window cannot establish those details. Cable protection, drainage and the frame need their own assessment.

Define the food/pharma washdown acceptance plan

Match the bridge to the instrument.

Recommended excitation is 5 V, with a 12 V maximum. Input resistance is 390 ±5 Ω and output resistance 350 ±5 Ω. Follow the exact supplied six-wire function chart, including sense and shield termination. Source zero balance is ±5% F.S.; review instrument input range and tare allowance together.

The source operating range is −10 to +50°C and compensated range −10 to +40°C. These temperatures do not establish a cleaning-cycle rating. Digital PLC output is a separate transmitter choice; dynamic settling requires assembly trials.

Review exact-model wiring and mounting checks

Compare capacity, mounting and bridge output.

These reference configurations use catalogue-revision data. Freeze the supplied drawing and acceptance scope before the sample order.

SPL-SSW-103

IP68 stainless single point bench cell

Stainless steel; grade to confirm · IP68 · C3 catalogue declaration

SPL-SSW-103 original mounting outline with millimetre dimensions and thread callouts; do not scale
Mounting outlineMillimetres · reference drawing

Reference outline, not a released production drawing. Download the PDF for its capacity-specific dimensions. Do not scale this image.

CapacityL × W × H (mm)Thread / engagementAnalog outputReference platform (mm)Select
6 kg150 × 25 × 40M6 / 12 mm2.0 ±10% mV/V500 × 400Request this variant
10 kg150 × 25 × 40M6 / 12 mm2.0 ±10% mV/V500 × 400Request this variant
20 kg150 × 25 × 40M6 / 12 mm2.0 ±10% mV/V500 × 400Request this variant
30 kg150 × 25 × 40M6 / 12 mm2.0 ±10% mV/V500 × 400Request this variant
50 kg150 × 25 × 40M6 / 12 mm2.0 ±10% mV/V500 × 400Request this variant
100 kg150 × 25 × 40M6 / 12 mm2.0 ±10% mV/V500 × 400Request this variant
Catalogue cable
6 mm diameter × 1500 mm; 6 conductors plus shield; confirm the supplied termination.
Input / output bridge resistance
390 ±5 Ω / 350 ±5 Ω
Recommended excitation
5 V; maximum 12 V
Compensated / operating temperature
−10 to +40°C / −10 to +50°C
vmin / full-scale deflection
Request exact-model values; not assigned by this reference
Wiring functions and configuration limits

Confirm the actual supplied cable chart before connection. Wire colours are model-specific.

EXC+
Green
EXC−
Black
SIG+
White
SIG−
Red
SEN+
Yellow
SEN−
Blue
Shield
Shield
  • IP68 declaration does not establish hot high-pressure cleaning, chemical compatibility or hygienic approval. Stainless alloy grade and sealing process are not specified.
  • Reference platform: 500 × 400 mm; include platter/fixture tare in the rated gross load and confirm corner-load acceptance.
  • M6 depth callouts are 12 mm; confirm actual bolt engagement, spacer stack and torque on the supplied drawing. No torque or thread pitch is inferred.
  • Static safe overload 150% F.S.; ultimate 200% F.S. is not an operating or impact-survival rating. Deflection and vmin are not published.
  • Cable-entry boss: diameter 14 mm, projection 7.5 mm beyond body. Confirm active mounting faces/engagement; do not assume all depicted mounting faces are used together.
  • The source wire-tail note denotes 8 mm lead-free tinned ends, not a whole-assembly compliance statement. Confirm the supplied cable termination.

C3 is a 2023 source-catalogue declaration, not an SPL certificate. Request exact supplied-model approval, calibration and corner-load evidence.

Choose the integration scope.

Request the bare cell, an overload-stop bench base, a compatible transmitter, or the mounting spacers and fasteners. Specify frame size, drainage, stop locations and acceptance criteria. These are RFQ options; the reference does not promise a qualified complete assembly or a universal accessory fit.

Reference revision and sample evidence.

Source review: 22 November 2026 · Catalogue edition: 2023

SPL-REF-20261122.2 reproduces this design’s 2023 catalogue data and mounting outline. C3 is a catalogue declaration. Request the supplied model’s certificate scope, calibration and corner-load report, controlled drawing and any required sealing test before releasing an OEM order. Full-scale deflection, vmin and measured settling time are not published in this reference.

Compare stainless selection requirements or view the other stainless reference designs. The unresolved IP67/IP68 editions for SPL-SSW-102 remain a separate review.

SPL-SSW-103 selection questions

Does IP68 mean this cell supports hot high-pressure washing?

The 2023 source catalogue declares IP68 for this design. It does not specify immersion depth or duration here, establish IP69K, or document compatibility with hot pressure jets, cleaning chemicals or a hygienic assembly. Supply the cleaning conditions so the exact supplied sealing variant and test evidence can be reviewed.

Which capacity fits a 500 × 400 mm bench platform?

The source lists 6, 10, 20, 30, 50 and 100 kg capacities with a 500 × 400 mm reference platform. Capacity must include the platform, fixtures and product. Confirm eccentric loading and any dynamic or handling loads separately; the listed envelope does not qualify every load distribution or finished scale.

What electrical interface does SPL-SSW-103 use?

The reference is an analog 2.0 ±10% mV/V bridge, with 390 ±5 ohm input resistance, recommended 5 V excitation and 12 V maximum excitation. Its cable chart identifies six conductors plus shield. RS485, EtherCAT and other PLC signals require a separately specified compatible transmitter.

Can I use a standard M6 bolt torque or a fixed overload-stop gap?

The outline marks M6 threads and 12 mm depth. Torque, bolt engagement through the actual spacer stack and stop-point movement require the supplied mechanical instructions. No bolt torque or full-scale deflection is assigned in this reference. A 150% static safe-overload declaration does not establish impact survival.

Is this a certified direct replacement for an existing sensor?

No validated replacement mapping or SPL certificate is assigned. The catalogue C3 declaration does not transfer an original manufacturer approval. Send the complete original code, capacity, drawing, cable chart and required approval so mechanical, electrical, platform and metrological compatibility can be reviewed.