Clear normal movement
G_min = G − T
Normal margin = G_min − normal movement. It must be strictly positive within the declared envelope.
ENGINEERING WORKSHEET
Screen mass, platform and a declared stop interval.
Go to the inputs and results ↓1 / CAPACITY SCREEN
kg values are masses. K = 1 is a neutral static arithmetic assumption. Enter your own reviewed multiplier; it does not validate impact energy, side force, eccentric load or dynamic accuracy.
Preparing worksheet controls. The manual method and reference sources remain below.
Send these declared inputs for engineering review2 / DECLARED MOVEMENT INTERVAL
Use maximum normal movement and manufacturer-approved limiting movement at the same stop point, direction and assembly conditions. All dimensions below are mm. The seven current SPL reference designs do not publish full-scale deflection, so no model gap is prefilled.
Add all four dimensions, the drawing/test source and same-point confirmation. Unknown travel cannot produce a gap setting.
Request a stop/base drawing review with these inputsWORKING PRINCIPLE / ONE LOAD PATH
A single-point design compensates position-related effects within its specified platform/load conditions. It does not remove the overturning moment or make every off-centre position error-free. The assembled scale still needs centre/corner verification.
Use E_screen = (m_net + m_tare) × K with consistent kg units. A displayed resolution or catalogue accuracy class does not establish allowable error for your full assembly. A higher capacity can change the available signal per unit product mass.
Review dynamic weigh-window inputs separately
| SPL source reference | Listed capacities | Platform reference | Full-scale deflection / vmin | Source |
|---|---|---|---|---|
| SPL-CMP-101 | 200 g–3 kg | 100 × 100 mm; check exact variant | Not supplied; request exact-model evidence | Reference PDF |
| SPL-CMP-102 | 300 g–5 kg | 200 × 200 mm; check exact variant | Not supplied; request exact-model evidence | Reference PDF |
| SPL-SSW-101 | 3 kg–200 kg | 600 × 500 mm; check exact variant | Not supplied; request exact-model evidence | Reference PDF |
| SPL-ALU-101 | 50 kg–500 kg | 600 × 600 mm; check exact variant | Not supplied; request exact-model evidence | Reference PDF |
| SPL-HVY-101 | 50 kg–1000 kg | Capacity pairing not assigned | Not supplied; request exact-model evidence | Reference PDF |
| SPL-SSW-102 | 50 kg–1000 kg | Capacity pairing not assigned | Not supplied; request exact-model evidence | Reference PDF |
| SPL-SSW-103 | 6 kg–100 kg | 500 × 400 mm; check exact variant | Not supplied; request exact-model evidence | Reference PDF |
Only a capacity-specific known platform pairing can pass an entered platform screen. The tool does not turn an unresolved IP grade or an unassigned larger-platform option into an affirmative match.
The SPL-SSW-101 source platform is 600 × 500 mm; SPL-ALU-101 lists 600 × 600 mm. A rated load that fits the mass screen can still fail the requested rectangular envelope or environment. Heavy capacity alone does not establish an 800 × 800 or 1,000 × 1,000 mm platform.
The outline at right supplies its own M6 and engagement callouts. Review pad contact, thread standard/depth, plate thickness, cable exit and free flexure travel on the controlled order drawing.
Compare source outlines and request the released assembly
STOP ARITHMETIC / SAME POINT AND DIRECTION
G_min = G − T
Normal margin = G_min − normal movement. It must be strictly positive within the declared envelope.
G_max = G + T
Limit margin = limiting movement − G_max. It must also be strictly positive. A positive value is only an arithmetic result.
The bounds, nominal gap and tolerance refer to one stop point/datum, travel direction and reviewed assembly/load state. Deflection at another point needs an actual geometry/stiffness relationship.
| Input | Evidence needed | Frequent omission |
|---|---|---|
| Maximum normal movement | Measured or approved worst operating movement at the stop point | Tare, eccentric load, frame movement and the defined reference datum |
| Limiting movement | Manufacturer/assembly-approved limit for the same point and direction | A load-percentage rating cannot be converted into travel without evidence |
| One-sided tolerance T | Conservative combined gap variation from the reviewed assembly stack | Setting repeatability, thermal effects, fastener and frame variation; no blind statistical cancellation |
| Nominal gap G | Proposed drawing value and inspection method | A dimensioned screw setting is not proof of peak-force control |
Every row below uses hypothetical normal movement 0.20 mm, limiting movement 0.50 mm and T = 0.02 mm. These are software examples, not measured SPL data or installation settings.
| Synthetic case | G (mm) | Interval (mm) | Normal / limit margin (mm) | Interpretation |
|---|---|---|---|---|
| Strictly within entered bounds | 0.30 | 0.28–0.32 | 0.08 / 0.18 | Interval arithmetic only; physical review remains |
| Touching normal boundary | 0.22 | 0.20–0.24 | 0 / 0.26 | Zero margin; not an accepted setting |
| Beyond limiting movement | 0.49 | 0.47–0.51 | 0.27 / −0.01 | Revise the interval or the reviewed design |
| Declared scenario | Arithmetic / source outcome | Useful next action |
|---|---|---|
| 50 kg net + 8 kg tare, K = 1.5 | 87 kg screened minimum; no impact or settling qualification | Filter the actual platform and environment, then review a source candidate |
| Same masses on 1,000 × 1,000 mm | No assigned current SPL capacity/platform pairing passes | Send the platform/load path for a custom or alternate-layout assessment |
| IP69K required | No currently qualified affirmative catalogue match in this dataset | Send cleaning conditions and required exact-model evidence |
| Travel or stop source missing | Gap setting remains unknown | Request the movement/assembly drawing; keep the declared mass screen separate |
Send the platen/fixtures, sensor interface, supports/feet, spacer thickness, stop locations, stiffness and inspection requirements. A centre stop does not automatically control a corner impact or lateral/torsional case.
Review transport restraints and load handling too. Static headroom and an interval worksheet do not establish survival under an arbitrary dropped mass. Ask for a documented fixture and controlled acceptance plan.
Prepare a matched SPL-BASE requestExample acceptance records should identify the load mass/placement, platform axes, environment, instrument/filter configuration and agreed error criteria. A factory fixture result does not automatically qualify your finished machine.
Use the sample and repeat-order release workflowSOURCE REVIEW / 22 NOVEMBER 2026
The SPL reference PDFs use the reviewed source catalogue revision. Independent manufacturer documents below support the identified original examples and installation distinctions; they do not assign their ratings, torque, pinout or approvals to an SPL configuration.
Add maximum net mass and the mass of the platen and all attached tooling, then apply your declared screening multiplier: E_screen = (net + tare) × K. This mass-based screen does not validate shock, side force, eccentric loading, dynamic accuracy or legal-for-trade performance.
There is no universally qualified factor in this tool. K = 1 is a neutral static arithmetic assumption. Choose and document the relevant machine load cases; falling objects, acceleration, vibration and stop contact require their own engineering analysis and trials.
No. Display zero or tare does not remove the physical mass carried by the load cell. Include the platen, belt or hopper, product and attached tooling in the load-path review.
No. Length and width are compared to the documented axes as entered. A rotated installation needs its own source drawing and review; an unassigned platform limit does not pass the dimension screen.
No. The movement at the actual stop point, permissible movement, stiffness, tolerances, temperature and load cases must be established. The current seven SPL reference designs have no published full-scale deflection in this catalogue, so this tool does not derive a model-specific gap.
Only that G − T exceeds the declared maximum normal movement and G + T remains below the declared limiting movement. It does not verify the evidence, certify a screw setting, establish impact survival or qualify the complete structure.
The worksheet marks a touching boundary separately and does not accept it. A zero allowance leaves no room beyond the entered bound; resolve the source, tolerance stack and assembly review before choosing a setting.
No. Capacity, measurement range, bridge output, platform, eccentricity and metrology must be reviewed together. A mechanical stop, transport restraint or alternate sensor architecture may be needed for particular load cases.
Send the entered mass, factor basis, platform axes, environment and any movement evidence for manual review. The inquiry link keeps those requirements without assigning an SPL candidate or inventing a capacity/platform pairing.
No. The presets and example table are synthetic software demonstrations. Their movement values do not describe any SPL model, approved base or recommended stop setting.
DRAWING + INPUTS + ACCEPTANCE SCOPE
Use the tool's review action to retain your entered values in the editable engineering brief. Attach the approved drawing, nameplate or test records in your own email application.
Return to my worksheet / observationsThe calculations and symptom lists organize a review. Agree the actual supplied model, assembly, source revisions and tests before release.