ENGINEERING WORKSHEET

Single point load cell design: capacity, platform and stops.

Screen mass, platform and a declared stop interval.

Go to the inputs and results ↓

1 / CAPACITY SCREEN

Screen net + tare.

Declared load and platform inputs

kg values are masses. K = 1 is a neutral static arithmetic assumption. Enter your own reviewed multiplier; it does not validate impact energy, side force, eccentric load or dynamic accuracy.

Preparing worksheet controls. The manual method and reference sources remain below.

Send these declared inputs for engineering review

2 / DECLARED MOVEMENT INTERVAL

Check a proposed stop gap against two movement bounds.

Use maximum normal movement and manufacturer-approved limiting movement at the same stop point, direction and assembly conditions. All dimensions below are mm. The seven current SPL reference designs do not publish full-scale deflection, so no model gap is prefilled.

Source-led stop inputs; all required for interval arithmetic

Add all four dimensions, the drawing/test source and same-point confirmation. Unknown travel cannot produce a gap setting.

Request a stop/base drawing review with these inputs

Keep the assumptions attached to the numbers.

WORKING PRINCIPLE / ONE LOAD PATH

The sensor carries tare even when the display reads zero.

  1. 1Net product + platen + attached tooling: physical gross mass
  2. 2Declared K: one screening assumption, with a documented basis
  3. 3Capacity and known platform axes: catalogue shortlist
  4. 4Drawings, eccentric/dynamic cases and acceptance: engineering review

A single-point design compensates position-related effects within its specified platform/load conditions. It does not remove the overturning moment or make every off-centre position error-free. The assembled scale still needs centre/corner verification.

Use E_screen = (m_net + m_tare) × K with consistent kg units. A displayed resolution or catalogue accuracy class does not establish allowable error for your full assembly. A higher capacity can change the available signal per unit product mass.

Review dynamic weigh-window inputs separately
microcapacity compact aluminum parallel beam transparent flexure potting and side cable — supplier-source product reference
SPL-CMP-102 reference geometry. Off-centre compensation operates within an agreed platform and load envelope; this image is not a performance test.

Seven source designs: capacity is known; deflection remains open.

SPL source referenceListed capacitiesPlatform referenceFull-scale deflection / vminSource
SPL-CMP-101200 g–3 kg100 × 100 mm; check exact variantNot supplied; request exact-model evidenceReference PDF
SPL-CMP-102300 g–5 kg200 × 200 mm; check exact variantNot supplied; request exact-model evidenceReference PDF
SPL-SSW-1013 kg–200 kg600 × 500 mm; check exact variantNot supplied; request exact-model evidenceReference PDF
SPL-ALU-10150 kg–500 kg600 × 600 mm; check exact variantNot supplied; request exact-model evidenceReference PDF
SPL-HVY-10150 kg–1000 kgCapacity pairing not assigned Not supplied; request exact-model evidenceReference PDF
SPL-SSW-10250 kg–1000 kgCapacity pairing not assigned Not supplied; request exact-model evidenceReference PDF
SPL-SSW-1036 kg–100 kg500 × 400 mm; check exact variantNot supplied; request exact-model evidenceReference PDF

Only a capacity-specific known platform pairing can pass an entered platform screen. The tool does not turn an unresolved IP grade or an unassigned larger-platform option into an affirmative match.

Match both platform axes before reviewing the mounting faces.

The SPL-SSW-101 source platform is 600 × 500 mm; SPL-ALU-101 lists 600 × 600 mm. A rated load that fits the mass screen can still fail the requested rectangular envelope or environment. Heavy capacity alone does not establish an 800 × 800 or 1,000 × 1,000 mm platform.

The outline at right supplies its own M6 and engagement callouts. Review pad contact, thread standard/depth, plate thickness, cable exit and free flexure travel on the controlled order drawing.

Compare source outlines and request the released assembly
SPL-SSW-101 own mounting outline with distinct fixing and loading interfaces
Source reference outline; do not scale the image or treat it as a released base drawing.

STOP ARITHMETIC / SAME POINT AND DIRECTION

Two inequalities define the interval check.

Clear normal movement

G_min = G − T

Normal margin = G_min − normal movement. It must be strictly positive within the declared envelope.

Engage before the entered limit

G_max = G + T

Limit margin = limiting movement − G_max. It must also be strictly positive. A positive value is only an arithmetic result.

Keep the source attached

The bounds, nominal gap and tolerance refer to one stop point/datum, travel direction and reviewed assembly/load state. Deflection at another point needs an actual geometry/stiffness relationship.

InputEvidence neededFrequent omission
Maximum normal movementMeasured or approved worst operating movement at the stop pointTare, eccentric load, frame movement and the defined reference datum
Limiting movementManufacturer/assembly-approved limit for the same point and directionA load-percentage rating cannot be converted into travel without evidence
One-sided tolerance TConservative combined gap variation from the reviewed assembly stackSetting repeatability, thermal effects, fastener and frame variation; no blind statistical cancellation
Nominal gap GProposed drawing value and inspection methodA dimensioned screw setting is not proof of peak-force control

Three synthetic intervals demonstrate the boundary handling.

Every row below uses hypothetical normal movement 0.20 mm, limiting movement 0.50 mm and T = 0.02 mm. These are software examples, not measured SPL data or installation settings.

Synthetic caseG (mm)Interval (mm)Normal / limit margin (mm)Interpretation
Strictly within entered bounds0.300.28–0.320.08 / 0.18Interval arithmetic only; physical review remains
Touching normal boundary0.220.20–0.240 / 0.26Zero margin; not an accepted setting
Beyond limiting movement0.490.47–0.510.27 / −0.01Revise the interval or the reviewed design
Run these synthetic cases in the worksheet

Screening outcomes lead to different review paths.

Declared scenarioArithmetic / source outcomeUseful next action
50 kg net + 8 kg tare, K = 1.587 kg screened minimum; no impact or settling qualificationFilter the actual platform and environment, then review a source candidate
Same masses on 1,000 × 1,000 mmNo assigned current SPL capacity/platform pairing passesSend the platform/load path for a custom or alternate-layout assessment
IP69K requiredNo currently qualified affirmative catalogue match in this datasetSend cleaning conditions and required exact-model evidence
Travel or stop source missingGap setting remains unknownRequest the movement/assembly drawing; keep the declared mass screen separate
Conceptual fixed spacer, free flexure and loaded-end stop load path; not a dimensional assembly
Mounting concept only. Centre, corner, lateral and transport cases need separate review.

Specify the complete base, rather than only the stop screw.

Send the platen/fixtures, sensor interface, supports/feet, spacer thickness, stop locations, stiffness and inspection requirements. A centre stop does not automatically control a corner impact or lateral/torsional case.

Review transport restraints and load handling too. Static headroom and an interval worksheet do not establish survival under an arbitrary dropped mass. Ask for a documented fixture and controlled acceptance plan.

Prepare a matched SPL-BASE request

Release the source revision before setting the assembly.

  1. 1Freeze the sensor, platen/frame, load cases, stop points and movement evidence.
  2. 2Agree fasteners, engagement, assembly tolerances and the controlled inspection method.
  3. 3Qualified personnel set and check the unloaded/normal-load assembly to the approved procedure.
  4. 4Record centre/corner, pre/post zero and dynamic operating checks within the model limits.
  5. 5Approve the sample and preserve the drawing, test conditions and change-control record.

Example acceptance records should identify the load mass/placement, platform axes, environment, instrument/filter configuration and agreed error criteria. A factory fixture result does not automatically qualify your finished machine.

Use the sample and repeat-order release workflow

SOURCE REVIEW / 22 NOVEMBER 2026

Original documents define their own models and conditions.

The SPL reference PDFs use the reviewed source catalogue revision. Independent manufacturer documents below support the identified original examples and installation distinctions; they do not assign their ratings, torque, pinout or approvals to an SPL configuration.

Capacity, platform and stop decisions

What is the starting capacity calculation?

Add maximum net mass and the mass of the platen and all attached tooling, then apply your declared screening multiplier: E_screen = (net + tare) × K. This mass-based screen does not validate shock, side force, eccentric loading, dynamic accuracy or legal-for-trade performance.

Which dynamic multiplier should every checkweigher use?

There is no universally qualified factor in this tool. K = 1 is a neutral static arithmetic assumption. Choose and document the relevant machine load cases; falling objects, acceleration, vibration and stop contact require their own engineering analysis and trials.

Does zeroing the display remove platen tare from the sensor?

No. Display zero or tare does not remove the physical mass carried by the load cell. Include the platen, belt or hopper, product and attached tooling in the load-path review.

Can the tool rotate a rectangular platform to make it fit?

No. Length and width are compared to the documented axes as entered. A rotated installation needs its own source drawing and review; an unassigned platform limit does not pass the dimension screen.

Is a gap of full-scale deflection plus 0.2 mm always valid?

No. The movement at the actual stop point, permissible movement, stiffness, tolerances, temperature and load cases must be established. The current seven SPL reference designs have no published full-scale deflection in this catalogue, so this tool does not derive a model-specific gap.

What does an interval within the entered movement bounds establish?

Only that G − T exceeds the declared maximum normal movement and G + T remains below the declared limiting movement. It does not verify the evidence, certify a screw setting, establish impact survival or qualify the complete structure.

Can a zero-margin interval be accepted?

The worksheet marks a touching boundary separately and does not accept it. A zero allowance leaves no room beyond the entered bound; resolve the source, tolerance stack and assembly review before choosing a setting.

Can a larger load cell solve every overload and accuracy issue?

No. Capacity, measurement range, bridge output, platform, eccentricity and metrology must be reviewed together. A mechanical stop, transport restraint or alternate sensor architecture may be needed for particular load cases.

What happens when no catalogue row fits?

Send the entered mass, factor basis, platform axes, environment and any movement evidence for manual review. The inquiry link keeps those requirements without assigning an SPL candidate or inventing a capacity/platform pairing.

Are the example movements measured SPL test results?

No. The presets and example table are synthetic software demonstrations. Their movement values do not describe any SPL model, approved base or recommended stop setting.

DRAWING + INPUTS + ACCEPTANCE SCOPE

Send the load assumptions and movement evidence together.

Use the tool's review action to retain your entered values in the editable engineering brief. Attach the approved drawing, nameplate or test records in your own email application.

Return to my worksheet / observations

Start a blank design inquiry

The calculations and symptom lists organize a review. Agree the actual supplied model, assembly, source revisions and tests before release.